The seismic tremor that shook Christchurch on February 22, 2011, not only shattered buildings but also the spirit of the city’s residents. Amidst the ruins, this design-focused thesis unravels two intertwining narratives, each essential to the city’s resurrection. At its core, this thesis probes the preservation of Christchurch’s memory and character, meticulously chronicling the lost heritage architecture and the subsequent urban metamorphosis. Beyond bricks and mortar, it also confronts the silent aftershocks - the pervasive mental health challenges stemming from personal losses and the disfigured cityscape. As a native of Christchurch, intimately connected to its fabric, my lens reflects not just on the architectural reconstruction but also on the emotional reconstruction. My experience as an autistic individual, a recently discovered facet of my identity, infuses this design journey with a distinct prism through which I perceive and interact with the world. The colourful sketches that drive the design process aren’t mere illustrations but manifestations of my interpretation of spaces and concepts, evoking joy and vitality—a testament to embracing diversity in design. Drawing parallels between healing my own traumas with my colourful and joyful neurodivergent worldview, I’ve woven this concept into proposals aimed at healing the city through whimsy, joy, and vibrant colours. Personal experiences during and post-earthquakes profoundly shape my design proposals. Having navigated the labyrinth of my own mental health amid the altered cityscape, I seek avenues for reconciliation, both personal and communal. The vibrant sketches and designs presented in this thesis encapsulate this vision—a fusion of vivid, unconventional interpretations and a dedication to preserving the essence of the original cityscape while still encouraging movement into the future
Recent seismic events, such as the 2010-2011 Canterbury earthquakes and the 2016 Kaikōura earthquakes, have shed light on issues with the seismic performance of glazing systems. This is attributed to the limited amount of research and consideration of glazing systems in design and assessments. Previous research and evidence from post-earthquake reconnaissance have shown that glazing systems pose a hazard due to falling glass. As such, it is vital to ensure that glazing systems are designed with the necessary levels of seismic performance. Furthermore, the post-earthquake repair of glass facades can be costly and time-consuming. Some previous research has been conducted to highlight the seismic performance and fragility of glazing systems. However, most prior research only focussed on life-safety issues of glazing systems and rarely on the serviceability of glazing systems. The serviceability of glazing systems, such as water-tightness, is a vital aspect of glazing systems as a low serviceability capacity will increase the likelihood of further damage which will increase economic losses. This is the aim of this research, to provide insight towards the seismic performance of glazing systems considering both the serviceability and ultimate limit state by generating insight into the behaviour of glazing systems and developing tools for the consideration of glazing systems in design and assessment. This will allow a value proposition for seismic detailing of glazing to be evaluated. In order to provide insight into the behaviour of glazing systems and a means for evaluating their seismic performance, this research firstly develops an applicable experimental testing procedure that allows for serviceability limit state tests on glazing units. This experimental testing procedure is used to obtain data on the vulnerability of general New Zealand glazing systems’ performance, specifically unitised glazing systems that are commonly used as commercial shopfront glazing system types. These glazing systems typically realised using aluminium framing with gaskets connecting the frame to the glass. After the experimental testing, numerical analyses calibrated to the experimental testing results are conducted to enable robust analyses of glazing systems’ fragility. Finally, a value proposition for glazing systems with seismic detailing is made by comparing the performance of glazing systems with seismic detailing and conventional glazing systems. This comparison is done using the PEER-PBEE method and the economic implications of each glazing system is shown. Suggestions for designers and stakeholders aimed at reducing costs related to the seismic performance of glazing systems is also shown. Using the novel experimental method developed in this research, three different full-scale glazing systems were tested. A total of 10 unitised glazing specimens were tested; three with standard detailing, three with seismic detailing and four that were structurally glazed. These tests evaluated three damage states (DS): loss of water-tightness (DS1), gasket damage (DS2), and glass or framing failure (DS3). The experimental method that was adopted is considered to be more desirable than the optional procedures set out in New Zealand glazing standards. The method does not require high-speed testing equipment and is easy to replicate by the industry. The test results show that water-tightness was lost at low drift levels, with the first leakage occurring at just 0.15% drift for one specimen, while a standard glazing system had a median drift capacity of 0.35%. In contrast, seismic glazing systems detailed to better accommodate in-plane movements, demonstrated a significantly higher median drift capacity of 1.88%. The numerical approach proposed in this research has shown that it is possible to numerically model the glazing-gasket interaction to conservatively predict the water-leakage drift (damage state 1). The modelling approach still needs further development if it were to be used for damage states DS2 and DS3. The last part of the research considered the value proposition for seismic glazing systems. This was achieved by applying the FEMA P-58 performance assessment framework to a number of case study buldings that are typical of New Zealand design. The results suggest that it may not be economically worthwhile to use well-detailed seismic glazing systems despite the considerably larger drift capacity they possess relative to standard systems. However, as the cost of seismic glazing systems reduces, and more information on repair costs for different damage states is obtained, the value proposition may change.
Reinforced concrete (RC) frame buildings designed according to modern design standards achieved life-safety objectives during the Canterbury earthquakes in 2010-11 and the Kaikōura earthquake in 2016. These buildings formed ductile plastic hinges as intended and partial or total building collapse was prevented. However, despite the fact that the damage level of these buildings was relatively low to moderate, over 60% of multi-storey RC buildings in the Christchurch central business district were demolished due to insufficient insurance coverage and significant uncertainty in the residual capacity and repairability of those buildings. This observation emphasized an imperative need to improve understanding in evaluating the post-earthquake performance of earthquake-damaged buildings and to develop relevant post-earthquake assessment guidelines. This thesis focuses on improving the understanding of the residual capacity and repairability of RC frame buildings. A large-scale five-storey RC moment-resisting frame building was tested to investigate the behaviour of earthquake-damaged and repaired buildings. The original test building was tested with four ground motions, including two repeated design-level ground motions. Subsequently, the test building was repaired using epoxy injection and mortar patching and re-tested with three ground motions. The test building was assessed using key concepts of the ATC-145 post-earthquake assessment guideline to validate its assessment procedures and highlight potential limitations. Numerical models were developed to simulate the peak storey drift demand and identify damage locations. Additionally, fatigue assessment of steel reinforcement was conducted using methodologies as per ATC-145. The residual capacity of earthquake-strained steel reinforcement was experimentally investigated in terms of the residual fatigue capacity and the residual ultimate strain capacity. In addition to studying the fatigue capacity of steel reinforcement, the fatigue damage demand was estimated using 972 ground motion records. The deformation limit of RC beams and columns for damage control was explored to achieve a low likelihood of requiring performance-critical repair. A frame component test database was developed, and the deformation capacity at the initiation of lateral strength loss was examined in terms of the chord rotation, plastic rotation and curvature ductility capacity. Furthermore, the proposed curvature ductility capacity was discussed with the current design curvature ductility limits as per NZS 3101:2006
The research presented in this thesis investigated the environmental impacts of structural design decisions across the life of buildings located in seismic regions. In particular, the impacts of expected earthquake damage were incorporated into a traditional life cycle assessment (LCA) using a probabilistic method, and links between sustainable and resilient design were established for a range of case-study buildings designed for different seismic performance objectives. These links were quantified using a metric herein referred to as the seismic carbon risk, which represents the expected environmental impacts and resource use indicators associated with earthquake damage during buildings’ life. The research was broken into three distinct parts: (1) a city-level evaluation of the environmental impacts of demolitions following the 2010/2011 Canterbury earthquake sequence in New Zealand, (2) the development of a probabilistic framework to incorporate earthquake damage into LCA, and (3) using case-study buildings to establish links between sustainable and resilient design. The first phase of the research focused on the environmental impacts of demolitions in Christchurch, New Zealand following the 2010/2011 Canterbury Earthquake Sequence. This large case study was used to investigate the environmental impact of the demolition of concrete buildings considering the embodied carbon and waste stream distribution. The embodied carbon was considered here as kilograms of CO2 equivalent that occurs on production, construction, and waste management stage. The results clearly demonstrated the significant environmental impacts that can result from moderate and large earthquakes in urban areas, and the importance of including environmental considerations when making post-earthquake demolition decisions. The next phase of the work introduced a framework for incorporating the impacts of expected earthquake damage based on a probabilistic approach into traditional LCA to allow for a comparison of seismic design decisions using a carbon lens. Here, in addition to initial construction impacts, the seismic carbon risk was quantified, including the impacts of seismic repair activities and total loss scenarios assuming reconstruction in case of non-reparability. A process-based LCA was performed to obtain the environmental consequence functions associated with structural and non-structural repair activities for multiple environmental indicators. In the final phase of the work, multiple case-study buildings were used to investigate the seismic consequences of different structural design decisions for buildings in seismic regions. Here, two case-study buildings were designed to multiple performance objectives, and the upfront carbon costs, and well as the seismic carbon risk across the building life were compared. The buildings were evaluated using the framework established in phase 2, and the results demonstrated that the seismic carbon risk can significantly be reduced with only minimal changes to the upfront carbon for buildings designed for a higher base shear or with seismic protective systems. This provided valuable insight into the links between resilient and sustainable design decisions. Finally, the results and observations from the work across the three phases of research described above were used to inform a discussion on important assumptions and topics that need to be considered when quantifying the environmental impacts of earthquake damage on buildings. These include: selection of a non-repairable threshold (e.g. a value beyond which a building would be demolished rather than repaired), the time value of carbon (e.g. when in the building life the carbon is released), the changing carbon intensity of structural materials over time, and the consideration of deterministic vs. probabilistic results. Each of these topics was explored in some detail to provide a clear pathway for future work in this area