This community-partnered thesis explores the impact of ReVision Youth Audits in promoting youth-friendly community spaces in Christchurch, a city undergoing long-term urban transformation following the 2010–2011 earthquakes. In partnership with ReVision, a not-for-profit organisation facilitating youth-led audits of public and community spaces, this research examines how audit recommendations have been implemented by organisations responsible for 23 previously audited sites. Using a mixed-methods approach, including an online stakeholder survey (n = 16) and semi-structured interviews (n = 2), the study identified variation in implementation outcomes, with non-profit organisations reporting higher adoption levels than local government entities. Stakeholders reported that commonly implemented recommendations included enhanced lighting, inclusive signage, additional seating, and youth-focused amenities such as murals, free Wi-Fi, and gender-neutral toilets. The average youth-friendliness score increased from 4.7 to 7.5 out of 10 following implementations, reflecting tangible improvements in accessibility, inclusivity, and youth engagement. Despite these gains, several barriers limited full implementation. Local government stakeholders cited procedural delays, regulatory frameworks, and funding cycles tied to long- term planning. At the same time, non-profits stakeholders faced constraints such as property ownership and limited influence over shared spaces. Challenges related to timing, staffing capacity, and the absence of follow-up mechanisms were also reported. Stakeholders recomended integrating youth input in the design process earlier, as several audits occurred after key planning phases. Feedback on the audit process was largely positive, with high ratings for the clarity of recommendations and the tool's credibility. However, stakeholders advocated for refinements when recording the audit recommendations to capture young people's lived experiences better and sustain youth involvement beyond the initial audit phase. The research demonstrates that the ReVision Youth Audit framework contributes to meaningful improvements in public spaces especially for youth and reinforces the value of youth-informed urban design. This research provides practical guidance for enhancing youth engagement in urban planning and improving the long-term utility of participatory audit frameworks, based on an analysis of both the factors that enabled and those that constrained the implementation of audit recommendations.
The devastating consequences of past events, such as the 2004 Indian Ocean and 2011 Tōhoku tsunamis, emphasise the need for continued improvement in resilience measures. Given that 80% of magnitude 8+ earthquakes occur on the Pacific Rim, New Zealand's tsunami risk is significant. This research develops a novel tsunami inundation model. The proposed model applies equations based on hydraulic principles, including energy conservation (friction loss). While it does not fully replicate hydrodynamic models, it maintains a two-dimensional approach and offers significant improvements over currently implemented simplified methods. It retains excellent computational efficiency (seconds to minutes) while achieving a significant increase in accuracy that is comparable to traditional hydrodynamic models, which typically take hours to days. Calibration of the roughness input variables to hydrodynamic modelling at Gisborne and Christchurch, New Zealand, optimised the model to achieve similarity index values of above 84% for inundation extent, while 77% of inundation depths were within ±1 m and over 93% within ±2 m. This research then produces the first nationally consistent tsunami exposure assessment for New Zealand using a physics-based modelling method. Using probabilistic shoreline wave amplitude data, the study generates high-resolution (10 m) inundation maps for seven return periods (50th and 84th percentiles). These maps are integrated with land cover and infrastructure data to quantify exposure and identify the most vulnerable locations. The results highlight exposure not only to the commonly studied cities but also to several provincial areas. The identification of exposure is the foremost step towards practical resilience efforts; however, understanding specific infrastructure impacts ensures that countermeasures and risk reduction practices are implemented. Therefore, a detailed evaluation of the NZTA Bridge Manual is conducted. Comparisons are made between the NZTA methodology and the rapid model developed in this research. The results reveal a significant overestimation of bridge and culvert exposure by NZTA methods. The study further highlights critical exposure locations for bridge and culvert assets. Flow depths calculated at bridge locations are significantly overestimated using the NZTA method compared to results derived from hydrodynamic modelling and the rapid model. This research then conducts component-level modelling of culvert assets, due to their identified vulnerability in the transportation network. At a 1:15 geometrical scale, laboratory experiments evaluated the response of different culvert set-ups to tsunami bores. The findings provide a detailed description into overtopping, flow regimes and pressure distributions and give laboratory experiments as validation studies for future numerical modelling and design improvements. Overall, this research performs a multi-modal tsunami inundation assessment, uniting macro-level exposure modelling with micro-level component responses by integrating modelling, exposure analysis, and experimental validation. The findings support refining current tsunami guidelines, improving infrastructure planning, and enhancing community preparedness. Overall, the study’s multi-model approach strengthens many elements of New Zealand’s ability to mitigate and respond to future tsunami events
According to TS 1170.5, designing a building to satisfy code-prescribed criteria (e.g., drift limit, member safety, P-Δ stability) at the ultimate limit state and relying on the inherent margins within the design code would lead to an acceptable mean annual frequency of collapse (λ꜀) in the range of 10−⁴ to 10−⁵. Modern performance objectives, such as λ꜀ and expected annual loss (EAL), are not explicitly considered. Although buckling-restrained braced frame (BRBF) buildings were widely adopted as lateral load-resisting systems for office and car park buildings in the Christchurch rebuild following the Canterbury earthquakes in New Zealand, there are currently no official guidelines for their design. The primary focus of this study is to develop a risk-targeted design framework for BRBF buildings that can achieve the performance objectives desired by stakeholders. To this extent, key factors influencing λ꜀ and EAL of BRBF buildings are identified. These factors include gusset plate design, number of storeys, design drift limit, BRBF beam-column connection, brace configuration, brace angle, brace material grade, and analysis method (equivalent lateral force vs. modal response spectrum). A novel 3D BRBF modelling approach capable of simulating out-of-plane buckling failure of buckling-restrained brace (BRB) gusset plates is developed. Prior experimental studies on sub-assemblies conducted elsewhere have demonstrated that gusset plates and end zones may buckle out of plane prematurely, before BRBs reach their maximum axial compression load carrying capacity. Current 2D BRBF macro models, typically used in research, cannot simulate this failure mode. A conventional 2D BRBF model underestimates the λ꜀ of a case-study 4-storey super-X configured steel BRBF building (designed according to NZS-3404) by a factor of two compared to the estimate from the proposed 3D model. These findings suggest that the current NZS-3404 gusset plate design method may undersize gusset plates and that using a 2D BRBF model in this case can significantly underestimate λ꜀. Three improved alternative gusset plate design methods that are easy to implement in practice are identified from the literature. Gusset plates in two case-study 4-storey steel BRBF buildings with super-X and diagonal configurations are designed using both the NZS-3404 method and alternative methods. All three alternative design methods are found to be conservative, resulting in an almost three-fold lower λ꜀ for both case-study BRBF buildings compared to those designed using the NZS-3404 method. Analysis results indicate that (i) bidirectional interaction has no significant effect on gusset plate buckling and (ii) mid-span gusset plates are more susceptible to buckling than corner gusset plates. A framework for seismic loss assessment using incremental dynamic analysis (IDA), called loss-oriented hazard-consistent incremental dynamic analysis (LOHC-IDA), is developed. IDA can be conducted with a generic record set, eliminating the arduous site-specific record selection required to conduct multiple stripe analysis (MSA). Traditional IDA, however, is limited in producing hazard-consistent estimates of engineering demand parameters (EDPs), which LOHC-IDA overcomes. LOHC-IDA improves upon existing methods by: (i) incorporating correlations among engineering demand parameters across intensity levels and (ii) using peak ground acceleration (PGA) to predict peak floor acceleration (PFA). For two case-study steel BRBF buildings, LOHC-IDA estimates the EAL and loss distributions conditioned on the intensity level that closely match the MSA results, with an average absolute error of 5%. The influence of factors beyond gusset plate design on the λ꜀ and EAL of 26 case-study steel BRBF buildings (designed in accordance with TS 1170.5) is examined. Hazard-consistent λ꜀ and EAL for these buildings are estimated using the FEMA P-58 loss and risk assessment framework. Among the 26 case-study buildings, 23 satisfy the maximum code-specified λ꜀ limit of 10−⁴. The EAL, normalised by the total building replacement cost, is highest for 2-storey BRBFs (0.22% on average), followed by 4-storey BRBFs (0.16% on average) and 8-storey BRBFs (0.11% on average). Reducing the design drift limit has the most significant effect on lowering λ꜀ (all BRBF designs were drift governed), followed by transitioning from pinned to moment-resisting beam-column connections, reducing the brace angle, and increasing brace strength. BRBF buildings designed using the equivalent lateral force method, on average, have a lower λ꜀ compared to those designed using the modal response spectrum method. Diagonally configured BRBFs exhibit the lowest λ꜀, followed by super- X and chevron configured BRBFs. Most design variables, apart from drift limit and beam-column connection, have limited influence on EAL. A simple method for EDP-targeted design of steel BRBF buildings is proposed. For this purpose, linear regression and CatBoost machine learning models are developed to predict steel BRBF building EDPs using peak storey drift ratio (PSDR) and PFA estimates from the 26 case-study buildings at intensity levels ranging from 80% to 0.5% probability of exceedance in 50 years. The R²ₐₔⱼ of these models is around 0.98, while the average prediction error is less than 10%. Fundamental period (T₁), total building height (Hₜ), and pseudospectral acceleration at T₁, denoted as Sₐ(T₁), are selected as the features to predict PSDR, while T₁, Hₜ, and PGA are the features selected to predict PFA. The EDP-targeted design has three steps: (i) for a given Hₜ value, the PSDR prediction model is used to identify a suitable T₁ that can achieve a desired PSDR target at the design intensity, (ii) a force-based design is then conducted iteratively to achieve the target T₁ by using an appropriate ductility factor and design drift limit, and (iii) based on the T₁ in the final design iteration, the PFA demand estimated by the PFA prediction models is used as a conservative input for the design of acceleration-sensitive non-structural elements. An equation to predict λ꜀ at the design stage is proposed for collapse risk-targeted seismic design of buildings. This equation comprises three principal components: reserve building strength, a proxy for effective structural stiffness, and reserve building deformation capacity. This equation is calibrated for the collapse risk-targeted design of BRBF buildings in New Zealand using results from 26 case-study BRBF buildings. The validity of this equation is demonstrated with three design verification examples designed to specific λ꜀ targets. Considering λ꜀ from hazard-consistent incremental dynamic analysis as the benchmark, the mean absolute percentage error in the design-stage prediction of λ꜀ of the verification buildings is approximately 10%.