An entry from Ruth Gardner's blog for 24 September 2011 entitled, "EQC Evaluation".
An entry from Roz Johnson's blog for 21 December 2011 entitled, "Loving Green".
A photograph of a map of CBD building evaluations as of 27 February 2011.
An entry from Ruth Gardner's blog for 22 September 2011 entitled, "Steady on Stilts".
An entry from Ruth Gardner's blog for 9 November 2011 entitled, "Amuri Abandoned".
A photograph of workers evaluating a crack in the footpath next to the Avon River.
An entry from Ruth Gardner's blog for 9 August 2011 entitled, "Sounding the Soil".
An entry from Ruth Gardner's blog for 20 August 2011 entitled, "Diverse Drilling".
An entry from Roz Johnson's blog for 4 May 2011 entitled, "My Unprofessional Geo Technical Report".
An entry from Ruth Gardner's blog for 5 October 2011 entitled, "Drilling Down".
An entry from Ruth Gardner's blog for 31 December 2011 entitled, "Awareness or Apprehension?".
A news item titled, "Lyttelton Tunnel", published on the Lyttelton Harbour Information Centre's website on Thursday, 29 September 2011.
The Asko Design store on Victoria Street has been given a yellow sticker. This was a building assessment system used following the February earthquake and indicates that this building has limited access and needs further evaluation.
The Surreal Hair & Beauty store on Victoria Street has been given a yellow sticker. This was a building assessment system used following the February earthquake and indicates that this building has limited access and needs further evaluation.
The Surreal Hair & Beauty store on Victoria Street has been given a yellow sticker. This was a building assessment system used following the February earthquake and indicates that this building has limited access and needs further evaluation.
A copy of the CanCERN online newsletter published on 28 October 2011
The Lyttelton Harbour Information Centre's "Community Earthquake Update" bulletin, published on Friday 12 August 2011.
A news item titled, "Parks and Reserves Update September 2011", published on the Lyttelton Harbour Information Centre's website on Friday, 23 September 2011.
Museums around the world are often affected by major catastrophes, and yet planning for these disasters is an often neglected aspect of museum practice. New Zealand is not immune from these events, as can be seen in the recent series of serious earthquakes in Christchurch in 2010 and 2011. This dissertation considers how prepared the New Zealand museum sector is to handle unexpected events that negatively affect its buildings, staff, operations and treasured collections. The central research question was: What is the overall state of emergency planning in the New Zealand museum sector? There was a significant gap in the literature, especially in the local context, as there has been only one other comparable study conducted in Britain, and nothing locally. This dissertation makes a valuable contribution to the field of museum studies by drawing on theory from relevant areas such as crises management literature and by conducting original empirical research on a topic which has received little attention hitherto. The research employed a number of methods, including a review of background secondary sources, a survey and interviews. After contextualising the study with a number of local examples, Ian online survey was then developed an which enabled precise understanding of the nature of current museum practices and policies around emergency planning. Following this I conducted several interviews with museum professionals from a variety of institutional backgrounds which explored their thoughts and feelings behind the existing practices within the industry. The findings of the research were significant and somewhat alarming: almost 40% of the museum and galleries in New Zealand do not have any emergency plan at all, and only 11% have what they considered ‘complete’ plans. The research revealed a clear picture of the current width and depth of planning, as well as practices around updating the plans and training related to them. Within the industry there is awareness that planning for emergencies is important, but museum staff typically lack the knowledge and guidance needed to conduct effective emergency planning. As a result of the analysis, several practical suggestions are presented aimed at improving emergency planning practices in New Zealand museums. However this study has implications for museum studies and for current museum practice everywhere, as many of the recommendations for resolving the current obstacles and problems are applicable anywhere in the world, suggesting that New Zealand museums could become leaders in this important area.
The "Lyttelton Review" newsletter for 5 December 2011, produced by the Lyttelton Harbour Information Centre.
The Lyttelton Harbour Information Centre's "Community Earthquake Update" bulletin, published on Friday 23 September 2011.
The former Lyttelton Fire Station on the corner of Sumner Road and Oxford Street. Broken stonework from the top of the building lies on the footpath where it fell. Members of the New Zealand Fire Service are evaluating the building.
The former Lyttelton Fire Station on the corner of Sumner Road and Oxford Street. Broken stonework from the top of the building lies on the footpath where it fell. Members of the New Zealand Fire Service are evaluating the building.
The Lyttelton Harbour Information Centre's "Community Earthquake Update" bulletin, published on Friday 22 July 2011.
The Lyttelton Harbour Information Centre's "Community Earthquake Update" bulletin, published on Friday 29 July 2011.
As the result of the September 4th 2010 Canterbury earthquake and associated aftershocks on February 22nd 2011 and June 13th 2011, final examinations in the two 100 level economics papers at Canterbury University were cancelled at short notice in semester one 2011. The final examination weightings were spread over the remaining assessments to obtain a final grade for students. This paper attempts to establish how different online assessment conditions affect final grade distributions when online assessments are substituted for an invigilated final examination. Pearson correlation coefficients and Spearman rank order correlation coefficients are used to show that there is a greater correlation between online quizzes and invigilated assessments when those quizzes are only available for a restricted period of time, compared to the whole semester. We find that online quizzes are more closely correlated with invigilated assessments when the first attempt at a quiz is recorded, as opposed to the highest of two attempts. We also find that using the first attempt leads to less grade disruption when compared to a “normal” semester that includes a final examination. Finally, the actual impact on student grades when online quizzes are substituted for a final examination is discussed.
Tourism is New Zealand’s fourth largest industry, providing jobs for thousands of New Zealanders and significant foreign capital for the nation’s economy. Of concern to ministry and industry decision makers is the “spatial yield” of these tourists which takes into account the spatial and temporal contributions of their movements in terms of economic, cultural and environmental impacts. We have developed an agent-based model of tourism movements to simulate these impacts and to allow for the evaluation of different scenarios (such as increases in petrol prices or variations in currency exchange rates) on the behaviours of those tourists. In order to develop realistic and grounded heuristics for the model, interview protocols were developed in order to identify the key drivers in tourists’ decision making process.
The sequence of earthquakes that has greatly affected Christchurch and Canterbury since September 2010 has again demonstrated the need for seismic retrofit of heritage unreinforced masonry buildings. Commencing in April 2011, the damage to unreinforced stone masonry buildings in Christchurch was assessed and recorded with the primary objective being to document the seismic performance of these structures, recognising that they constitute an important component of New Zealand’s heritage architecture. A damage statistics database was compiled by combining the results of safety evaluation placarding and post-earthquake inspections, and it was determined that the damage observed was consistent with observations previously made on the seismic performance of stone masonry structures in large earthquakes. Details are also given on typical building characteristics and on failure modes observed. Suggestions on appropriate seismic retrofit and remediation techniques are presented, in relation also to strengthening interventions that are typical for similar unreinforced stone masonry structures in Europe.
An as-built reinforced concrete (RC) frame building designed and constructed according to pre-1970s code design construction practice has been recently tested on the shake table at the University of Canterbury. The specimen, 1/2.5 scaled version of the original prototype, consists of two 3-storey 2-bay asymmetric frames in parallel, one interior and one exterior, jointed together by transverse beams and floor slabs. Following the benchmark test, a retrofit intervention has been proposed to rehabilitate the tested specimen. In this paper, detailed information on the assessment and design of the seismic retrofit procedure using GFRP (glass fibre reinforced polymer) materials is given for the whole frame. Hierarchy of strength and sequence of events (damage mechanisms) in the panel zone region are evaluated using a moment-axial load (M-N) interaction performance domain, according to a performance-based retrofit philosophy. Specific limit states or design objectives are targeted with attention given to both strength and deformation limits. In addition, an innovative retrofit solution using FRP anchor dowels for the corner beam-column joints with slabs is proposed. Finally, in order to provide a practical tool for engineering practice, the retrofit procedure is provided in a step-by step flowchart fashion.
Extended Direct Analysis (EDA), developed at the University of Canterbury, is an advance on the AISC Direct Analysis method for the analysis of frames subjected to static forces. EDA provides a faster, simple and more rational way to properly consider the second-order effects, initial residual stresses (IRS) and the initial imperfections or steel structures under one directional loading than conventional analysis methods. This research applied the EDA method to quantify the effect of member overstrength on frame behaviour for a single storey frame. Also, the effects of IRS, which were included in the EDA static analysis, but which are not considered explicitly in non-linear seismic analysis, were evaluated in two ways. Firstly, they were considered for simple structures subject to increasing cyclic displacement in different directions. Secondly, incremental dynamic analysis with realistic ground motion was used to quantify the likely effect of IRS in earthquakes. It was found that, contrary to traditional wisdom and practice, greater member strengths can result in lower frame strengths for frames under monotonic lateral loading. The structural lateral capacity of the overstrength case was reduced by 6% compared to the case using the dependable member strengths. Also, it resulted significantly different in member demands. Therefore, it is recommended that when either plastic analysis or EDA is used, that both upper and lower bounds on the likely member strength should be considered to determine the total frame strength and the member demands. Results of push-pull analysis under displacement control showed that for IRS ratio, gamma < 0.5 and axial compressive force ratio, N*/Ns, up to 0.5, IRS did affect the structural behaviour in the first half cycle. However, the behavior in the later cycles was not significantly affected. It also showed that the effect of initial residual stresses in the frame was less significant than for the column alone when the column was subjected to similar axial compressive force. The incremental dynamic analysis results from both cantilever column and the three-storey steel frame showed that by increasing gamma = 0 to 0.5, the effect of IRS on seismic responses, based on the 50% confidence level, was less than 3% for N*/Ns, up to 0.5.