QuakeStory 701
Articles, UC QuakeStudies
A story submitted by Anonymous to the QuakeStories website.
A story submitted by Anonymous to the QuakeStories website.
A story submitted by Emma to the QuakeStories website.
A story submitted by Matthew F to the QuakeStories website.
Summary of oral history interview with Ella about her experiences of the Canterbury earthquakes.
Summary of oral history interview with Michelle about her experiences of the Canterbury earthquakes.
Summary of oral history interview with Alice Ridley about her experiences of the Canterbury earthquakes.
A story submitted by Anonymous to the QuakeStories website.
Summary of oral history interview with Emily about her experiences of the Canterbury earthquakes.
A story submitted by Melissa to the QuakeStories website.
A story submitted by Anonymous to the QuakeStories website.
A story submitted by Ginny Larsen to the QuakeStories website.
A story submitted by Pauline to the QuakeStories website.
A story submitted by Jennifer to the QuakeStories website.
A story submitted by Alasdair Wright to the QuakeStories website.
A story submitted by Hilary Lakeman to the QuakeStories website.
A story submitted by Sarah Dreyer to the QuakeStories website.
An entry from Deb Robertson's blog for 26 August 2014 entitled, "Election time".The entry was downloaded on 2 November 2016.
An entry from Deb Robertson's blog for 22 December 2014 entitled, "...a well-worn path...."The entry was downloaded on 3 November 2016.
A story submitted by Sue Hamer to the QuakeStories website.
A story submitted by Lin to the QuakeStories website.
A story submitted by Joan Curry to the QuakeStories website.
An entry from Deb Robertson's blog for 2 September 2014 entitled, "The heart expands when it is broken [four years]".The entry was downloaded on 2 November 2016.
The current seismic design practice for reinforced concrete (RC) walls has been drawn into question following the unsatisfactory performance of several RC wall buildings during the Canterbury earthquakes. An overview of current research being undertaken at the University of Auckland into the seismic behaviour of RC walls is presented. The main objectives of this research project are to understand the observed performance of RC walls in Christchurch, quantify the seismic loads on RC walls, and developed improved design procedures for RC walls that will assist in revisions to the New Zealand Concrete Structures Standard. A database summarising the performance of RC wall buildings in the Christchurch CBD was collated to identify damage modes and case-study buildings. A detailed investigation is underway to verify the seismic performance of lightly reinforced concrete walls and initial numerical modeling and small-scale tests are presented in addition to details of planned experimental tests of RC walls. Numerical modelling is being used to understand the potential influence that interactions between walls and other structural elements have on the seismic response of buildings and the loads generated on RC walls. The results from finite element analysis of a severely damaged RC wall in Christchurch highlighted the effect that the floor diaphragms have on the distribution of shear stains in the wall.
The Christchurch earthquakes have highlighted the importance of low-damage structural systems for minimising the economic impacts caused by destructive earthquakes. Post-tensioned precast concrete walls have been shown to provide superior seismic resistance to conventional concrete construction by minimising structural damage and residual drifts through the use of a controlled rocking mechanism. The structural response of unbonded post-tensioned precast concrete wall systems, with and without additional energy dissipating elements, were investigated by means of pseudo-static cyclic, snap back and forced vibration testing with shake table testing to be completed. Two types of post-tensioned rocking wall system were investigated; a single unbonded post-tensioned precast concrete wall or Single Rocking Wall (SRW) and a system consisting of a Precast Wall with End Columns (PreWEC). The equivalent viscous damping (EVD) was evaluated using both the pseudo-static cyclic and snap back test data for all wall configurations. The PreWEC configurations showed an increase in EVD during the snap back tests in comparison to the cyclic test response. In contrast the SRW showed lower EVD during the snap back tests in comparison to the SRW cyclic test response. Despite residual drifts measured during the pseudo-static cyclic tests, negligible residual drift was measured following the snap back tests, highlighting the dynamic shake-down that occurs during the free vibration decay. Overall, the experimental tests provided definitive examples of the behaviour of posttensioned wall systems and validated their superior performance compared to reinforced concrete construction when subjected to large lateral drifts.