Search

found 3 results

Images, UC QuakeStudies

A scanned copy of a photograph of the He-Ne Continuous Gas Laser used in David Lockwood's MSc research at the University of Canterbury. David explains that the photograph shows "the complete experimental system, including the horn-shaped acoustic chamber in front and the operating laser in the rear".

Research papers, University of Canterbury Library

Natural disasters are highly traumatic for those who experience them, and they can have an immense and often lasting emotional impact (Cox et al., 2008). Emotion has been studied in linguistics through its enactment in language, and this field of research has increased over the past decades. Despite this, the expression of emotion in post-disaster narratives is a largely unexplored field of research. This thesis investigates how emotion is expressed in narratives taken from the QuakeBox corpus (Walsh et al., 2013), recorded, following the Christchurch earthquakes, in 2012 and rerecorded in 2019. I take a mixed methods approach, combining computer-based emotion recognition software and discourse analytic techniques, to explore the expression of emotion at both a broad and narrow level. Two emotion recognition programs, Empath (Fast et al., 2016) and Speechbrain (Ravanelli et al., 2021), are employed to measure the levels of positive and negative emotion detected in a wide dataset of participants, which are investigated in relation to the gender and age of participants, and the temporal difference between the first and second QuakeBox recordings. In a second phase, a subset of these participants’ narratives was analysed qualitatively, exploring the co-construction of emotion and identity through a social constructionist lens and examining the societal Discourses present in the earthquake narratives. The findings highlight the relevance of gender in the expression of emotion. Female speakers have higher levels of positive emotion than non-female speakers in the findings of both emotion recognition programs, and there is a clear gendered difference in the construction of identity in the narratives, influencing the expression of emotion. The expression of emotion also appears to be mediated by New Zealand culture. Within this, a Discourse of the Christchurch earthquakes emerges, with motifs of luck, gratitude, and community, which reflects the values of the people of Christchurch at the time. Findings reinforced in both phases of the analysis also indicate differences between the lexical content and acoustic features in the emotion expressions, supporting previous research that argues that the expression of emotion, as a performative act, does not reflect the speaker’s inner state directly. This research adds a new dimension to (socio)linguistic research on emotion, as well as providing insight into how crisis survivors display emotion in their post-disaster narratives.

Research papers, University of Canterbury Library

Field surveys and experimental studies have shown that light steel or timber framed plasterboard partition walls are particularly vulnerable to earthquake damage prompting the overarching objective of this research, which is to further the development of low damage seismic systems for non-structural partition walls in order to facilitate their adoption by industry to assist with reducing the losses associated with the maintenance and repair cost of buildings across their design life. In particular, this study focused on the behaviour of steel-framed partition walls systems with novel detailing that aim to be “low-damage” designed according to common practice for walls used in commercial and institutional buildings in New Zealand. This objective was investigated by (1) investigating the performance of a flexible track system proposed by researchers and industry by experimental testing of full-scale specimens; (2) investigating the performance of the seismic gap partition wall systems proposed in a number of studies, further developed in this study with input from industry, by experimental testing of full-scale specimens; and (3) investigating the potential implications of using these systems compared with traditionally detailed partition wall systems within multi-storey buildings using the Performance Based Earthquake Engineering loss assessment methodology. Three full-scale testing frames were designed in order to replicate, under controlled laboratory conditions, the effects of seismic shaking on partition walls within multi-storey buildings by the application of quasi-static uni-directional cyclic loading imposing an inter-storey drift. The typical configuration for test specimens was selected to be a unique “y-shape”, including one angled return wall, with typical dimensions of approximately 2400 mm along the main wall and 600 mm along (approximately) the returns walls with a height of 2405 mm from floor to ceiling. The specimens were aligned within test frames at an oblique angle to the direction of loading in order to investigate bi- directional effects. Three wall specimens with flexible track detailing, two identical plane specimens and the third including a doorway, were tested. The detailing involved removing top track anchors within the proximity of wall intersections, thus allowing the tracks to ‘bow’ out at these locations. Although the top track anchors were specified to be removed the proximity of wall intersections, a construction error was made whereby a single top track slab to concrete anchor was left in at the three-way wall junction. Despite this error, the experimental testing was deemed worthwhile since such errors will also occur in practice and because the behaviour of the wall can be examined with this fixing in mind. The specimens also included an acoustic/fire sealant at the top lining to floor boundary. In addition to providing drift capacities, the force-displacement behaviour is also reported, the dissipated energy was computed, and the parameters of the Wayne-Stewart hysteretic model were fitted to the results. The specimen with the door opening behaved significantly different to the plane specimens: damage to the doorway specimen began as cracking of the wallboard propagating from the corners of the doorway following which the L- and Y- shaped junctions behaved independently, whereas damage to the plane specimens began as cracking of the wallboard at the top of the L-junction and wall system deformed as a single unit. The results suggest that bi-directional behaviour is important even if its impact cannot be directly quantified by the experiments conducted. Damage to sealant implies that the bond between plasterboard and sealant is important for its seismic performance. Careful quality control is advised as defects in the bond may significantly impact its ability to withstand seismic movement. Two specimens with seismic gap detailing were tested: a steel stud specimen and a timber stud specimen. Observed drift capacities were significantly greater than traditional plasterboard partition systems. Equations were used to predict the drift at which damage state 1 (DS1) and damage state 2 (DS2) would initiate. The equation used to estimate the drift at the onset of DS1 accurately predicted the onset of plaster cracking but overestimated the drift at which the gap filling material was damaged. The equation used to predict the onset of DS2 provided a lower bound for both specimens and also when used to predict results of previous experimental tests on seismic gap systems. The gap-filling material reduced the drift at the onset of DS1, however, it had a beneficial effect on the re-centring behaviour of the linings. Out-of-plane displacements and return wall configuration did not appear to significantly impact the onset of plaster cracking in the specimens. A loss assessment according to the PBEE methodology was conducted on four steel MRF case study buildings: (1) a 4-storey building designed for the Christchurch region, (2) a 4-storey building designed for the Wellington region, (3) a 12-storey building designed for the Christchurch region, and (4) a 12- storey building designed for the Wellington region. The fragility parameters for a traditional partition system, the flexible track partition system, and the seismic gap steel stud and timber stud partition systems were included within the loss assessment. The order (lowest to highest) of each system in terms of the expected annual losses of each building when incorporating the system was, (1) the seismic gap timber stud system, (2) the seismic gap steel stud system, (3) the traditional/baseline system, and (4) the flexible track system. For the seismic gap timber stud system, which incurred the greatest reduction in expected annual losses for each case study building, the reduction in expected annual losses in comparison to the losses found when using the traditional system ranged from a 5% to a 30% reduction. This reinforces the fact that while there is a benefit to the using low damage partition systems in each building the extent of reduction in expected annual losses is significantly dependent on the particular building design and its location. The flexible track specimens had larger repair costs at small hazard levels compared to the traditional system but smaller repair costs at larger hazard levels. However, the resulting expected annual losses for the flexible track system was higher than the traditional system which reinforces findings from past studies which observed that the greatest contribution to expected annual losses arises from low to moderate intensity shaking seismic events (low hazard levels).