A digitally manipulated image of a damaged wooden wall. The photographer comments, "And the walls came tumbling down".
Cracked wall
An entry from Roz Johnson's blog for 24 December 2011 entitled, "Retaining Walls and Earthquakes".
A photograph of the Poetica Urban Poetry wall. Details of the opening event are chalked on the wall.
Pages 1 and 2 of a 2014 Wall Planner published in the Christchurch Press on Monday 9 December 2013.
Pages 1 and 2 of a 2014 Wall Planner published in the Christchurch Press on Friday 13 December 2013.
A close up of the entrance to the cathedral. Bricks have fallen from the wall causing damage to the balustrade. Bracing has been placed against the front wall to limit further damage.
A photograph of a room in the Diabetes Centre which has been walled off using tarpaulins. Cracks in the wall have been filled with epoxy resin.
A photograph of a room in the Diabetes Centre. The panelling has been taken off the walls, exposing the wooden framing, insulation, and wires.
It's been revealed that the Earthquake Commission knew a wall which crushed two people in Christchurch's February earthquake was at risk of collapsing.
Nothing wrong with this carpark building; that's just a mural on one of the structural shear walls.
A photograph of a kitchen in the Diabetes Centre. The panelling has been removed from the wall of the kitchen, exposing the wooden frame and several pipes and wires.
Light timber framed (LTF) structures provide a cost-effective and structurally efficient solution for low-rise residential buildings. This paper studies seismic performance of single-storey LTF buildings sheathed by gypsum-plasterboards (GPBs) that are a typical lining product in New Zealand houses. Compared with wood-based structural panels, GPBs tend to be more susceptible to damage when they are used in bracing walls to resist earthquake loads. This study aims to provide insights on how the bracing wall irregularity allowed by the current New Zealand standard NZS 3604 and the in-plane rigidity of ceiling diaphragms affect the overall seismic performance of these GPB-braced LTF buildings. Nonlinear time-history analyses were conducted on a series of single-storey baseline buildings with different levels of bracing wall irregularities and ceiling diaphragm rigidity. The results showed significant torsional effect caused by the eccentric bracing wall layout with semi-rigid/rigid ceiling diaphragms. On average, bracing wall drift demand caused by the extreme bracing wall irregularities was three times of that in the regular bracing wall layout under the rigid diaphragm assumption. This finding agreed well with the house survey after the 2011 Canterbury Earthquake in which significantly more damage was observed in the houses with irregular bracing wall layouts and relatively rigid diaphragms. Therefore, it is recommended to limit the level of bracing wall eccentricity and ensure the sufficiently rigid diaphragms to avoid excessive damage in these LTF buildings in future events.
Graffiti on a brick wall reads "Pray hope and don't worry". The photographer comments, "Seen on a wall on Moorhouse Avenue, Christchurch".
The front of Christ Church Cathedral. The upper part of the front wall has crumbled leaving the inside space exposed. Steel bracing has been placed against the front wall to limit further damage.
The front of Christ Church Cathedral. The upper part of the front wall has crumbled leaving the inside space exposed. Steel bracing has been placed against the front wall to limit further damage.
The front of Christ Church Cathedral. The upper part of the front wall has crumbled leaving the inside space exposed. Steel bracing has been placed against the front wall to limit further damage.
A wall on the former site of Piko Wholefoods. A damaged part of the wall is covered with a graffiti paste-up of an elastoplast, with a speech bubble reading, "You poor thing".
Exposed wall after the demolition of the adjoining building. The wall has been graffitied, and in front are a set of recycling, rubbish and organic bins with some other bits of furniture.
The damaged Carlton Hotel with scaffolding on one side supporting the walls. On the other side, the wall has crumbled, exposing the interior, and leaving a pile of building rubble on the footpath.
Wall moved/cracked by liquification
A photograph of a woman applying filler to a concrete-block wall, in preparation for painting it to become the Poetica Urban Poetry wall.
The increasing prevalence of mixed-material buildings that combine concrete walls and steel frames in New Zealand, coupled with a lack of specific design and detailing guidelines for concrete wall-steel beam connections, underscores the need for comprehensive research to ensure that these structures behave as intended during earthquakes. Bolted web plate connections, commonly found in steel framing systems, are typically used to connect steel beams to concrete walls. These connections are idealised as pinned during design. However, research on steel framing systems has shown that these connections can develop significant stiffness and moment resistance when subjected to large rotations during seismic loading, potentially leading to brittle failure when used in concrete wall to steel beam applications. This thesis was written to understand the seismic performance of concrete wall-steel beam bolted web plate connections, providing experimental evidence, numerical modelling insights, and design recommendations to address critical gaps in current design practices. The study is divided into three phases. First, a review of 50 concrete wall-steel frame buildings in Auckland and Christchurch was conducted to understand current design practices and typical connection details. The findings revealed significant variation in design and detailing practices and a lack of specific guidelines for concrete wall-steel beam connections. Second, an experimental programme was conducted on four full-scale concrete wall-steel beam sub-assemblages, each incorporating variations in connection detailing. The tests were designed to quantify the rotation capacity of concrete wall-steel beam connections, identify failure modes and investigate the effectiveness of potential connection improvements. Results demonstrated that concrete wall-steel beam bolted web plate connections designed using current design standards and following existing practices are vulnerable to non-ductile failure characterised by concrete breakout. However, using slotted holes in the web plate and bent reinforcing bar anchors instead of headed stud anchors improved connection rotation capacity. Third, a numerical model of a case study building was developed on OpenSeesPy, with different connection conditions assumed based on the experimental results. Pushover and time history analyses were conducted to evaluate the implications of different connection conditions (pinned vs non-pinned) on global building response and local member demands. The findings revealed that using non-pinned connection conditions does not significantly affect the global building response and shear and bending moment demands on lateral load-resisting elements. However, doing so generates overstrength moments on the connections that induce different actions on out-of-plane concrete walls connected to steel beams. Synthesising findings from all three phases, this thesis concludes with a proposed design procedure for concrete wall-steel beam connections based on a capacity design approach to ensure ductile failure modes and suppress brittle ones. Key recommendations include selecting appropriate bolt hole geometry and anchorage, providing sufficient rotation capacity, and accounting for connection overstrength in global analyses
A close up of the damaged stonework of Christ Church Cathedral. The upper part of the front wall has crumbled leaving the inside space exposed. Steel bracing has been placed against the wall to limit further damage.
A close up of the front of Christ Church Cathedral. The upper part of the front wall has crumbled leaving the inside space exposed. Steel bracing has been placed against the front wall to limit further damage.
A close up of the damaged stonework of Christ Church Cathedral. The upper part of the front wall has crumbled leaving the inside space exposed. Steel bracing has been placed against the wall to limit further damage.
A red-stickered house with cracks running down the brick wall. The house has also separated slightly from the foundations and is now on a lean. The brick wall on the house next door has partially crumbled.
A photograph of the wooden frame of a wall in the Diabetes Centre. The panelling has been removed from the wall, exposing the frame and several pipes and wires underneath.
A photograph of several panels hanging from the ceiling of the Diabetes Centre. The panelling has been taken off the wall to the right, exposing the wooden structure beneath.
A close up of the front of Christ Church Cathedral. The upper part of the front wall has crumbled leaving the inside space exposed. Bracing has been placed against the front wall to limit further damage.