The Christchurch earthquakes have highlighted the importance of low-damage structural systems for minimising the economic impacts caused by destructive earthquakes. Post-tensioned precast concrete walls have been shown to provide superior seismic resistance to conventional concrete construction by minimising structural damage and residual drifts through the use of a controlled rocking mechanism. The structural response of unbonded post-tensioned precast concrete wall systems, with and without additional energy dissipating elements, were investigated by means of pseudo-static cyclic, snap back and forced vibration testing with shake table testing to be completed. Two types of post-tensioned rocking wall system were investigated; a single unbonded post-tensioned precast concrete wall or Single Rocking Wall (SRW) and a system consisting of a Precast Wall with End Columns (PreWEC). The equivalent viscous damping (EVD) was evaluated using both the pseudo-static cyclic and snap back test data for all wall configurations. The PreWEC configurations showed an increase in EVD during the snap back tests in comparison to the cyclic test response. In contrast the SRW showed lower EVD during the snap back tests in comparison to the SRW cyclic test response. Despite residual drifts measured during the pseudo-static cyclic tests, negligible residual drift was measured following the snap back tests, highlighting the dynamic shake-down that occurs during the free vibration decay. Overall, the experimental tests provided definitive examples of the behaviour of posttensioned wall systems and validated their superior performance compared to reinforced concrete construction when subjected to large lateral drifts.
The current seismic design practice for reinforced concrete (RC) walls has been drawn into question following the unsatisfactory performance of several RC wall buildings during the Canterbury earthquakes. An overview of current research being undertaken at the University of Auckland into the seismic behaviour of RC walls is presented. The main objectives of this research project are to understand the observed performance of RC walls in Christchurch, quantify the seismic loads on RC walls, and developed improved design procedures for RC walls that will assist in revisions to the New Zealand Concrete Structures Standard. A database summarising the performance of RC wall buildings in the Christchurch CBD was collated to identify damage modes and case-study buildings. A detailed investigation is underway to verify the seismic performance of lightly reinforced concrete walls and initial numerical modeling and small-scale tests are presented in addition to details of planned experimental tests of RC walls. Numerical modelling is being used to understand the potential influence that interactions between walls and other structural elements have on the seismic response of buildings and the loads generated on RC walls. The results from finite element analysis of a severely damaged RC wall in Christchurch highlighted the effect that the floor diaphragms have on the distribution of shear stains in the wall.
A photograph of a woman applying filler to a concrete-block wall, in preparation for painting it to become the Poetica Urban Poetry wall.
A concrete block wall with a large diagonal crack running through it. The photographer comments, "This wall has fascinated me. It has cracked across in a dead straight diagonal line during one of Christchurch's many earthquakes. How could this have occurred?".
A digitally manipulated image of a damaged fence. Concrete blocks have fallen from the wall leaving a large gap, through which autumn leaves are visible.
A detail of damage to the interior wall of the Durham Street Methodist Church. Plaster and concrete have fallen away from the wall, baring the stone work.
Slender precast concrete wall panels are currently in vogue for the construction of tall single storey warehouse type buildings. Often their height to thickness ratio exceed the present New Zealand design code (NZS 3101) limitations of 30:1. Their real performance under earthquake attack is unknown. Therefore, this study seeks to assess the dynamic performance of slender precast concrete wall panels with different base connection details. Three base connections (two fixed base and one rocking) from two wall specimens with height to thickness ratios of 60:1 were tested under dynamic loading. The two fixed based walls had longitudinal steel volumes of 1.27% to 0.54% and were tested on the University of Canterbury shaking table to investigate their proneness to out-of-plane buckling. Based on an EUler-type theoretical formula derived as part of the study, an explanation is made as to why walls with high in-plane capacity are more prone to buckling. The theory was validated against the present and past experimental evidence. The rocking base connection designed and built in accordance with a damage avoidance philosophy was tested on the shaking table in a similar fashion to the fixed base specimens. Results show that in contrast with their fixed base counterparts, rocking walls can indeed fulfil a damage-free design objective while also remaining stable under strong earthquake ground shaking.
A photograph of flying pigs painted on concrete blocks in a retaining wall. The photograph is captioned by BeckerFraserPhotos, "Decorated retaining wall in Cunningham Terrace, Lyttelton".
A photograph of the earthquake damage to a building on Oxford Terrace. The wall in front of the car park has collapsed, the concrete blocks spilling onto the footpath in front.
A photograph of a flying pig painted on a concrete block in a retaining wall. The photograph is captioned by BeckerFraserPhotos, "Decorated retaining wall in Cunningham Terrace, Lyttelton".
Damage to a car parking building on Lichfield Street. Part of the concrete wall has crumbled, exposing steel reinforcing rods within, and damaging an artwork painted on the wall.
A photograph of a blue moon painted on a concrete block in a retaining wall. The photograph is captioned by BeckerFraserPhotos, "Decorated retaining wall in Cunningham Terrace, Lyttelton".
A patch of brickwork from a demolished building remains on the concrete wall of the adjoining building.
One landscape colour digital photograph taken on 14 July 2011 showing the temporary repairs made to the retaining wall in the middle of Ripon Street. The temporary wall replaces two sections of red stone wall which collapsed in the June 2011 Earthquake. It is made from stacked concrete cubes with coarse fill and the top is covered with black pla...
A photograph of the earthquake-damaged to a house in Christchurch. The far wall has collapsed and many of the concrete blocks have spilled into the garden in front. Emergency tape has been draped in front of the wall as a cordon. A red sticker has also been stuck on the furthest window, indicating that the house is unsafe to enter.
The 2011, 6.3 magnitude Christchurch earthquake in New Zealand caused considerable structural damage. It is believed that this event has now resulted in demolition of about 65-70% of the building stock in the Central Business District (CBD), significantly crippling economic activities in the city of Christchurch. A major concern raised from this event was adequacy of the current seismic design practice adopted for reinforced concrete walls due to their poor performance in modern buildings. The relatively short-duration earthquake motion implied that the observed wall damage occurred in a brittle manner despite adopting a ductile design philosophy. This paper presents the lessons learned from the observed wall damage in the context of current state of knowledge in the following areas: concentrating longitudinal reinforcement in wall end regions; determining wall thickness to prevent out-of-plane wall buckling; avoiding lap splices in plastic hinge zones; and quantifying minimum vertical reinforcement. http://www.2eceesistanbul.org/
A photograph of a tag on a wall made of concrete blocks. The wall is near the railway tracks which run under the Durham Street over bridge. The tag reads, "JFK".
A photograph captioned by BeckerFraserPhotos, "A warning sign spray-painted on a concrete wall in Manchester Street".
A major lesson from the 2011 Christchurch earthquake was the apparent lack of ductility of some lightly reinforced concrete (RC) wall structures. In particular, the structural behaviour of the critical wall in the Gallery Apartments building demonstrated that the inelastic deformation capacity of a structure, as well as potentially brittle failure of the reinforcement, is dependent on the level of bond deterioration between reinforcement and surrounding concrete that occurs under seismic loading. This paper presents the findings of an experimental study on bond behaviour between deformed reinforcing bars and the surrounding concrete. Bond strength and relative bond slip was evaluated using 75 pull-out tests under monotonic and cyclic loading. Variations of the experiments include the loading rate, loading history, concrete strength (25 to 70 MPa), concrete age, cover thickness, bar diameter (16 and 20 mm), embedded length, and the position of the embedded bond region within the specimen (deep within or close to free surface). Select test results are presented with inferred implications for RC structures.
A photograph of building rubble on a cleared site on Tuam Street. Graffiti can be seen on the concrete wall.
Axial elongation of reinforced concrete (RC) plastic hinges has previously been observed in a range of laboratory experiments, and more recently was observed in several Christchurch buildings following the 2010/2011 Canterbury earthquakes. Axial restraint to plastic hinges is provided by adjacent structural components such as floors as the plastic hinges elongate, which can significantly alter the performance of the plastic hinge and potentially invalidate the capacity design strength hierarchy of the building. Coupling beams in coupled wall systems are particularly susceptible to axial restraint effects due to their importance in the strength hierarchy, the high ductility demands that they experience, and the large stiffness of bounding walls. From computational modelling it has been found that ignoring axial restraint effects when designing coupled walls can result in significantly increased strength, reduced ductility and reduced energy dissipation capacity. The complexity of the topic merits further research to better account for realistic restraint effects when designing coupled walls.
One landscape colour digital photograph taken on 28 April 2012 showing a painting representing Nero fiddling while Rome burnt. The painting was executed on a large curved concrete block of a temporary retaining wall in Cunningham Terrace, Lyttelton. Artist The retaining walls above and below Cunningham Terrace were severely damaged by the 22 Feb...
A house on Dorset Street with a damaged retaining wall. The concrete blocks have been stacked on the footpath in front.
A cracked wall made from rocks and concrete in Clifton. The words, "No. 5 The Spur", have been painted on it.
During the 2010/2011 Canterbury earthquakes, several reinforced concrete (RC) walls in multi-storey buildings formed a single crack in the plastic hinge region as opposed to distributed cracking. In several cases the crack width that was required to accommodate the inelastic displacement of the building resulted in fracture of the vertical reinforcing steel. This type of failure is characteristic of RC members with low reinforcement contents, where the area of reinforcing steel is insufficient to develop the tension force required to form secondary cracks in the surrounding concrete. The minimum vertical reinforcement in RC walls was increased in NZS 3101:2006 with the equation for the minimum vertical reinforcement in beams also adopted for walls, despite differences in reinforcement arrangement and loading. A series of moment-curvature analyses were conducted for an example RC wall based on the Gallery Apartments building in Christchurch. The analysis results indicated that even when the NZS 3101:2006 minimum vertical reinforcement limit was satisfied for a known concrete strength, the wall was still susceptible to sudden failure unless a significant axial load was applied. Additionally, current equations for minimum reinforcement based on a sectional analysis approach do not adequately address the issues related to crack control and distribution of inelastic deformations in ductile walls.
One landscape colour digital photograph taken on 28 April 2012 showing a painting of a winged pig flying against a cloud. The painting was executed on a large curved concrete block of a temporary retaining wall in Cunningham Terrace, Lyttelton. The retaining walls above and below Cunningham Terrace were severely damaged by the 22 February 2011 ...
One landscape colour digital photograph taken on 28 April 2012 showing a painting of a steam train with seven visible carriages or wagons. A caption painted below the train reads "The Gravy Train" The painting was executed in blue on large curved concrete blocks of a temporary retaining wall in Cunningham Terrace, Lyttelton. The retaining walls...
A photograph of large bags of concrete supporting a retaining wall. The photograph is captioned by BeckerFraserPhotos, "Cunningham Terrace, Lyttelton".
Seen through a cordon fence, traces of bricks from a demolished building adhere to the concrete wall of the adjoining building, also being demolished.
Seen through a cordon fence, traces of bricks from a demolished building adhere to the concrete wall of the adjoining building, also being demolished.