The purpose of this research is to investigate men’s experiences of the 2016 7.8 magnitude Kaikōura earthquake and Tsunami. While, research into the impacts of the earthquake has been conducted, few studies have examined how gender shaped people’s experiences of this natural hazard event. Analysing disasters through a gender lens has significantly contributed to disaster scholarship in identifying the resilience and vulnerabilities of individuals and communities pre- and post-disaster (Fordham, 2012; Bradshaw, 2013). This research employs understandings of masculinities (Connell, 2005), to examine men’s strengths and challenges in responding, recovering, and coping following the earthquake. Qualitative inquiry was carried out in Northern Canterbury and Marlborough involving 18 face-to-face interviews with men who were impacted by the Kaikōura earthquake and its aftermath. Interview material is being analysed using thematic and narrative analysis. Some of the preliminary findings have shown that men took on voluntary roles in addition to their fulltime paid work resulting in long hours, poor sleep and little time spent with family. Some men assisted wives and children to high ground then drove into the tsunami zone to check on relatives or to help evacuate people. Although analysis of the findings is currently ongoing, preliminary findings have identified that the men who participated in the study have been negatively impacted by the 2016 Kaikōura earthquake. A theme identified amongst participants was an avoidance to seek support with the challenges they were experiencing due to the earthquake. The research findings align with key characteristics of masculinity, including demonstrating risky behaviours and neglecting self or professional care. This study suggests that these behaviours affect men’s overall resilience, and thus the resilience of the wider community.
Research Report: 2010-02 The objective in writing this report is to provide a guide to structural engineers on how to assess the potential seismic performance of existing hollow-core floors in buildings and the steps involved in the design of new floors. Hollow-core units in New Zealand do not contain stirrups within the precast concrete section. This is due to the way that they are manufactured. The only reinforcement in the great majority of hollow-core units consists of pretensioned strands that are located close to the soffit. A consequence of this is that hollow-core units have a number of potential brittle failure modes that can occur when adverse structural actions are induced in the units. These adverse actions can be induced in a major earthquake due to the relative vertical, horizontal and rotational displacements that occur between hollow-core units and adjacent structural elements, such as beams or structural walls. A number of large scale structural tests backed up by analytical research has shown that extensive interaction occurs between floors containing prestressed precast units and other structural elements, such as walls and beams. The constraint that prestressed units in a floor can apply to adjacent beams can result in an increase in strength of the beams to a considerably greater strength than that indicated in editions of the New Zealand Structural Concrete Standard published prior to 2006. The extent of this increase is such that it could in some cases result in the development of a non-ductile failure mechanism instead of the ductile failure mechanism assumed in the design. Prestressed floor units tie the floor bays together leaving a weak section where the floor joins to supporting structural elements. The restraint provided by the prestress restricts the opening of cracks within the bay. In the event of an earthquake this restraint can result in wide cracks developing at some of the boundaries to floor bays. These cracks may have a significant influence on the performance of the floor when it acts as a diaphragm to transfer seismic forces to the lateral force resisting structural elements in the building. The report contains details of; 1. The different failure modes, which may be induced in hollow-core floors, and the failure modes that may develop in a buildings due to the presence of hollow-core units in the floors; 2. Criteria that may be used to assess the magnitude of the design earthquake which may be safely resisted by a hollow-core floor in a building; 3. Details of how construction practice related to the use of hollow-core floors in New Zealand has changed over the last five decades. This highlights particular aspects that need to be considered in carrying out an assessment of existing hollow-core floors; 4. Information on how a new hollow-core floor may be designed to be consistent with the Earthquake Actions Standard, NZS1170.5: 2004 and the Structural Concrete Standard, NZS3101: 2006 (plus Amendment 2); 5. A review of the research findings relevant to the behaviour of New Zealand hollow-core floors under earthquake conditions. Research that was used to develop the assessment and design criteria is described together with details of how the different criteria were developed from this work.
One of the most controversial issues highlighted by the 2010-2011 Christchurch earthquake series and more recently the 2016 Kaikoura earthquake, has been the evident difficulty and lack of knowledge and guidelines for: a) evaluation of the residual capacity damaged buildings to sustain future aftershocks; b) selection and implementation of a series of reliable repairing techniques to bring back the structure to a condition substantially the same as prior to the earthquake; and c) predicting the cost (or cost-effectiveness) of such repair intervention, when compared to fully replacement costs while accounting for potential aftershocks in the near future. As a result of such complexity and uncertainty (i.e., risk), in combination with the possibility (unique in New Zealand when compared to most of the seismic-prone countries) to rely on financial support from the insurance companies, many modern buildings, in a number exceeding typical expectations from past experiences at an international level, have ended up being demolished. This has resulted in additional time and indirect losses prior to the full reconstruction, as well as in an increase in uncertainty on the actual relocation of the investment. This research project provides the main end-users and stakeholders (practitioner engineers, owners, local and government authorities, insurers, and regulatory agencies) with comprehensive evidence-based information to assess the residual capacity of damage reinforced concrete buildings, and to evaluate the feasibility of repairing techniques, in order to support their delicate decision-making process of repair vs. demolition or replacement. Literature review on effectiveness of epoxy injection repairs, as well as experimental tests on full-scale beam-column joints shows that repaired specimens have a reduced initial stiffness compared with the undamaged specimen, with no apparent strength reduction, sometimes exhibiting higher displacement ductility capacities. Although the bond between the steel and concrete is only partially restored, it still allows the repaired specimen to dissipate at least the same amount of hysteretic energy. Experimental tests on buildings subjected to earthquake loading demonstrate that even for severe damage levels, the ability of the epoxy injection to restore the initial stiffness of the structure is significant. Literature review on damage assessment and repair guidelines suggests that there is consensus within the international community that concrete elements with cracks less than 0.2 mm wide only require cosmetic repairs; epoxy injection repairs of cracks less and 2.0 mm wide and concrete patching of spalled cover concrete (i.e., minor to moderate damage) is an appropiate repair strategy; and for severe damaged components (e.g., cracks greater than 2.0 mm wide, crushing of the concrete core, buckling of the longitudinal reinforcement) local replacement of steel and/or concrete in addition to epoxy crack injection is more appropriate. In terms of expected cracking patterns, non-linear finite element investigations on well-designed reinforced concrete beam-to-column joints, have shown that lower number of cracks but with wider openings are expected to occur for larger compressive concrete strength, f’c, and lower reinforcement content, ρs. It was also observed that the tensile concrete strength, ft, strongly affects the expected cracking pattern in the beam-column joints, the latter being more uniformly distributed for lower ft values. Strain rate effects do not seem to play an important role on the cracking pattern. However, small variations in the cracking pattern were observed for low reinforcement content as it approaches to the minimum required as per NZS 3101:2006. Simple equations are proposed in this research project to relate the maximum and residual crack widths with the steel strain at peak displacement, with or without axial load. A literature review on fracture of reinforcing steel due to low-cycle fatigue, including recent research using steel manufactured per New Zealand standards is also presented. Experimental results describing the influence of the cyclic effect on the ultimate strain capacity of the steel are also discussed, and preliminary equations to account for that effect are proposed. A literature review on the current practice to assess the seismic residual capacity of structures is also presented. The various factors affecting the residual fatigue life at a component level (i.e., plastic hinge) of well-designed reinforced concrete frames are discussed, and equations to quantify each of them are proposed, as well as a methodology to incorporate them into a full displacement-based procedure for pre-earthquake and post-earthquake seismic assessment.